{"_buckets": {"deposit": "ff8fd484-ff21-43c3-b0d6-5ba08b7b7130"}, "_deposit": {"created_by": 23, "id": "5163", "owner": "23", "owners": [23], "owners_ext": {"displayname": "", "username": ""}, "pid": {"revision_id": 0, "type": "recid", "value": "5163"}, "status": "published"}, "_oai": {"id": "oai:meral.edu.mm:recid/5163", "sets": ["user-um"]}, "communities": ["um"], "item_1583103067471": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer", "subitem_1551255648112": "en"}]}, "item_1583103085720": {"attribute_name": "Description", "attribute_value_mlt": [{"interim": "This research work is to determine the accuracy of SPECTRO XEPOS EDXRF Spectrometer at the Experimental Nuclear Physics Lab, Department of Physics, University of Mandalay and it also intends to inform the current performance of this Spectrometer. In order to obtain the reliable accuracy of this Spectrometer, every step of sample preparation, X-Ray measurement and data analysis were thoroughly performed. To determine the accuracy of SPECTRO XEPOS EDXRF Spectrometer IAEA-SL-1 (Lake Sediment), IAEA-SL-3 (Lake Sediment), IAEA-359 (Cabbage), IAEA-413 (Algae), IAEA-A-13 (Animal Blood) and NIST-2710 a (Montana Soil) were used. Two pellets of each Certified Reference Material were prepared for X-Ray measurement. Ten-Time measurements of each pellet were conducted."}]}, "item_1583103108160": {"attribute_name": "Keywords", "attribute_value_mlt": [{"interim": "SPECTRO XEPOS EDXRF Spectrometer"}, {"interim": "Accuracy of the Spectrometer"}, {"interim": "Certified Reference Materials Introduction"}]}, "item_1583103120197": {"attribute_name": "Files", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2020-09-03"}], "displaytype": "preview", "download_preview_message": "", "file_order": 0, "filename": "Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer.pdf", "filesize": [{"value": "449 Kb"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_0", "mimetype": "application/pdf", "size": 449000.0, "url": {"url": "https://meral.edu.mm/record/5163/files/Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer.pdf"}, "version_id": "cb8ef592-3b44-48a4-87ca-361b31bcfe35"}]}, "item_1583103131163": {"attribute_name": "Journal articles", "attribute_value_mlt": [{"subitem_journal_title": "Univeristy of Mandalay Research Journal", "subitem_volume": "8"}]}, "item_1583105942107": {"attribute_name": "Authors", "attribute_value_mlt": [{"subitem_authors": [{"subitem_authors_fullname": "Kay Khaing Oo"}, {"subitem_authors_fullname": "Nwe Nwe Aung"}]}]}, "item_1583108359239": {"attribute_name": "Upload type", "attribute_value_mlt": [{"interim": "Publication"}]}, "item_1583108428133": {"attribute_name": "Publication type", "attribute_value_mlt": [{"interim": "Journal article"}]}, "item_1583159729339": {"attribute_name": "Publication date", "attribute_value": "2017-09-03"}, "item_title": "Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer", "item_type_id": "21", "owner": "23", "path": ["1582963739756", "1582967025340"], "permalink_uri": "http://hdl.handle.net/20.500.12678/0000005163", "pubdate": {"attribute_name": "Deposited date", "attribute_value": "2020-09-03"}, "publish_date": "2020-09-03", "publish_status": "0", "recid": "5163", "relation": {}, "relation_version_is_last": true, "title": ["Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer"], "weko_shared_id": -1}
  1. University of Mandalay
  1. University of Mandalay
  2. Department of Physics

Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer

http://hdl.handle.net/20.500.12678/0000005163
http://hdl.handle.net/20.500.12678/0000005163
3f5d8dce-55b9-45cb-9ac0-72db0d49b29f
ff8fd484-ff21-43c3-b0d6-5ba08b7b7130
None
Preview
Name / File License Actions
Determination Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer.pdf (449 Kb)
license.icon
Publication type
Journal article
Upload type
Publication
Title
Title Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer
Language en
Publication date 2017-09-03
Authors
Kay Khaing Oo
Nwe Nwe Aung
Description
This research work is to determine the accuracy of SPECTRO XEPOS EDXRF Spectrometer at the Experimental Nuclear Physics Lab, Department of Physics, University of Mandalay and it also intends to inform the current performance of this Spectrometer. In order to obtain the reliable accuracy of this Spectrometer, every step of sample preparation, X-Ray measurement and data analysis were thoroughly performed. To determine the accuracy of SPECTRO XEPOS EDXRF Spectrometer IAEA-SL-1 (Lake Sediment), IAEA-SL-3 (Lake Sediment), IAEA-359 (Cabbage), IAEA-413 (Algae), IAEA-A-13 (Animal Blood) and NIST-2710 a (Montana Soil) were used. Two pellets of each Certified Reference Material were prepared for X-Ray measurement. Ten-Time measurements of each pellet were conducted.
Keywords
SPECTRO XEPOS EDXRF Spectrometer, Accuracy of the Spectrometer, Certified Reference Materials Introduction
Journal articles
Univeristy of Mandalay Research Journal
8
Back
0
0
views
downloads
See details
Views Downloads

Versions

Ver.1 2020-09-03 06:59:05.041178
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Export

OAI-PMH
  • OAI-PMH DublinCore
Other Formats
  • JSON

Confirm


Back to MERAL


Back to MERAL