{"created":"2020-09-03T06:52:25.645400+00:00","id":5163,"links":{},"metadata":{"_buckets":{"deposit":"ff8fd484-ff21-43c3-b0d6-5ba08b7b7130"},"_deposit":{"created_by":23,"id":"5163","owner":"23","owners":[23],"owners_ext":{"displayname":"","email":"myanila@mu.edu.mm","username":""},"pid":{"revision_id":0,"type":"recid","value":"5163"},"status":"published"},"_oai":{"id":"oai:meral.edu.mm:recid/5163","sets":["1582963739756","1582963739756:1582967025340"]},"communities":["um"],"item_1583103067471":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer","subitem_1551255648112":"en"}]},"item_1583103085720":{"attribute_name":"Description","attribute_value_mlt":[{"interim":"This research work is to determine the accuracy of SPECTRO XEPOS EDXRF Spectrometer at the Experimental Nuclear Physics Lab, Department of Physics, University of Mandalay and it also intends to inform the current performance of this Spectrometer. In order to obtain the reliable accuracy of this Spectrometer, every step of sample preparation, X-Ray measurement and data analysis were thoroughly performed. To determine the accuracy of SPECTRO XEPOS EDXRF Spectrometer IAEA-SL-1 (Lake Sediment), IAEA-SL-3 (Lake Sediment), IAEA-359 (Cabbage), IAEA-413 (Algae), IAEA-A-13 (Animal Blood) and NIST-2710 a (Montana Soil) were used. Two pellets of each Certified Reference Material were prepared for X-Ray measurement. Ten-Time measurements of each pellet were conducted."}]},"item_1583103108160":{"attribute_name":"Keywords","attribute_value_mlt":[{"interim":"SPECTRO XEPOS EDXRF Spectrometer"},{"interim":"Accuracy of the Spectrometer"},{"interim":"Certified Reference Materials Introduction"}]},"item_1583103120197":{"attribute_name":"Files","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2020-09-03"}],"displaytype":"preview","filename":"Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer.pdf","filesize":[{"value":"449 Kb"}],"format":"application/pdf","licensetype":"license_0","url":{"url":"https://meral.edu.mm/record/5163/files/Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer.pdf"},"version_id":"cb8ef592-3b44-48a4-87ca-361b31bcfe35"}]},"item_1583103131163":{"attribute_name":"Journal articles","attribute_value_mlt":[{"subitem_journal_title":"Univeristy of Mandalay Research Journal","subitem_volume":"8"}]},"item_1583105942107":{"attribute_name":"Authors","attribute_value_mlt":[{"subitem_authors":[{"subitem_authors_fullname":"Kay Khaing Oo"},{"subitem_authors_fullname":"Nwe Nwe Aung"}]}]},"item_1583108359239":{"attribute_name":"Upload type","attribute_value_mlt":[{"interim":"Publication"}]},"item_1583108428133":{"attribute_name":"Publication type","attribute_value_mlt":[{"interim":"Journal article"}]},"item_1583159729339":{"attribute_name":"Publication date","attribute_value":"2017-09-03"},"item_title":"Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer","item_type_id":"21","owner":"23","path":["1582963739756","1582967025340"],"publish_date":"2020-09-03","publish_status":"0","recid":"5163","relation_version_is_last":true,"title":["Determination of Accuracy of SPECTRO XEPOS EDXRF Spectrometer"],"weko_creator_id":"23","weko_shared_id":-1},"updated":"2021-12-13T01:20:29.685494+00:00"}