Log in
Language:

MERAL Myanmar Education Research and Learning Portal

  • Top
  • Universities
  • Ranking
To
lat lon distance
To

Field does not validate



Index Link

Index Tree

Please input email address.

WEKO

One fine body…

WEKO

One fine body…

Item

{"_buckets": {"deposit": "ea493719-a5a1-435c-97d4-2281c6c24936"}, "_deposit": {"id": "3890", "owners": [], "pid": {"revision_id": 0, "type": "recid", "value": "3890"}, "status": "published"}, "_oai": {"id": "oai:meral.edu.mm:recid/3890", "sets": ["user-ucsy"]}, "communities": ["ucsy"], "item_1583103067471": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "A QRS Detection Method Based on Signal Energy", "subitem_1551255648112": "en"}]}, "item_1583103085720": {"attribute_name": "Description", "attribute_value_mlt": [{"interim": "This paper presents a method for detection ofECG QRS complexes using signal energy. This system reliablyrecognizes QRS complexes based upon digital analyses of slope,amplitude, and width. In order to reduce false detections causedby noises in ECG signals, a digital band pass filter is alsoincorporated. This filtering permits use of low thresholds,thereby increasing detection sensitivity. This system can detectaccurately on ECG signals having many diverse signalscharacteristics QRS morphologies and heart rate changes byautomatically adjusting the thresholds and parametersperiodically. The effectiveness of the algorithm has been testedby using recording obtained from the MIT-BIH arrhythmiadatabase. The results showed that overall accuracy of detectionrates is 81% for various heartbeats such as normal beat, pacedbeat, premature ventricular contraction, atrial premature beat,left bundle branch block and right bundle branch block beat."}]}, "item_1583103108160": {"attribute_name": "Keywords", "attribute_value": []}, "item_1583103120197": {"attribute_name": "Files", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2019-08-02"}], "displaytype": "preview", "download_preview_message": "", "file_order": 0, "filename": "A QRS Detection Method Based on Signal Energy.pdf", "filesize": [{"value": "10 Kb"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 10000.0, "url": {"url": "https://meral.edu.mm/record/3890/files/A QRS Detection Method Based on Signal Energy.pdf"}, "version_id": "0fe4d580-6b05-47f5-82ac-b8d16df09bbe"}]}, "item_1583103131163": {"attribute_name": "Journal articles", "attribute_value_mlt": [{"subitem_issue": "", "subitem_journal_title": "Third Local Conference on Parallel and Soft Computing", "subitem_pages": "", "subitem_volume": ""}]}, "item_1583103147082": {"attribute_name": "Conference papers", "attribute_value_mlt": [{"subitem_acronym": "", "subitem_c_date": "", "subitem_conference_title": "", "subitem_part": "", "subitem_place": "", "subitem_session": "", "subitem_website": ""}]}, "item_1583103211336": {"attribute_name": "Books/reports/chapters", "attribute_value_mlt": [{"subitem_book_title": "", "subitem_isbn": "", "subitem_pages": "", "subitem_place": "", "subitem_publisher": ""}]}, "item_1583103233624": {"attribute_name": "Thesis/dissertations", "attribute_value_mlt": [{"subitem_awarding_university": "", "subitem_supervisor(s)": [{"subitem_supervisor": ""}]}]}, "item_1583105942107": {"attribute_name": "Authors", "attribute_value_mlt": [{"subitem_authors": [{"subitem_authors_fullname": "Latt, Tin Mg"}]}]}, "item_1583108359239": {"attribute_name": "Upload type", "attribute_value_mlt": [{"interim": "Publication"}]}, "item_1583108428133": {"attribute_name": "Publication type", "attribute_value_mlt": [{"interim": "Article"}]}, "item_1583159729339": {"attribute_name": "Publication date", "attribute_value": "2009-08-03"}, "item_1583159847033": {"attribute_name": "Identifier", "attribute_value": "http://onlineresource.ucsy.edu.mm/handle/123456789/1612"}, "item_title": "A QRS Detection Method Based on Signal Energy", "item_type_id": "21", "owner": "1", "path": ["1597824273898"], "permalink_uri": "http://hdl.handle.net/20.500.12678/0000003890", "pubdate": {"attribute_name": "Deposited date", "attribute_value": "2019-08-02"}, "publish_date": "2019-08-02", "publish_status": "0", "recid": "3890", "relation": {}, "relation_version_is_last": true, "title": ["A QRS Detection Method Based on Signal Energy"], "weko_shared_id": -1}
  1. University of Computer Studies, Yangon
  2. Conferences

A QRS Detection Method Based on Signal Energy

http://hdl.handle.net/20.500.12678/0000003890
http://hdl.handle.net/20.500.12678/0000003890
32e2a0ff-08c1-4e27-a647-cc77c255eddd
ea493719-a5a1-435c-97d4-2281c6c24936
None
Preview
Name / File License Actions
A A QRS Detection Method Based on Signal Energy.pdf (10 Kb)
Back
0
0
views
downloads
See details
Views Downloads

Versions

Ver.1 2020-09-01 13:45:05.844292
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Export

OAI-PMH
  • OAI-PMH DublinCore
Other Formats
  • JSON

Confirm


Back to MERAL


Back to MERAL