{"_buckets": {"deposit": "ca7de646-2731-4629-823b-ef3f89c40f41"}, "_deposit": {"id": "2125", "owners": [], "pid": {"revision_id": 0, "type": "recid", "value": "2125"}, "status": "published"}, "_oai": {"id": "oai:meral.edu.mm:recid/2125", "sets": ["user-uy"]}, "communities": ["ccm", "ccp", "kyauksetu", "ltc", "maas", "miit", "mlmu", "mmu", "mtlu", "mtu", "mub", "mude", "mufl", "pathein", "scu", "suoe", "tcu", "tgu", "tuh", "tum", "ucsm", "ucsmtla", "ucsmub", "ucspathein", "ucstaungoo", "ucsy", "udmm", "udmy", "uit", "um", "um1", "um2", "umkn", "umm", "uphy", "urj", "uvs", "uy", "yau", "ydbu", "ytu", "yude", "yueco", "yufl", "yuoe"], "control_number": "2125", "item_1583103067471": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Construction of High Voltage Power Supply Unit for GM Counter", "subitem_1551255648112": "en"}]}, "item_1583103085720": {"attribute_name": "Description", "attribute_value_mlt": [{"interim": "High Voltage Power Supply Unit is essential for\r nuclear radiation detection or counting system. A high voltage\r power supply unit that is suitable to use with GM (Geiger\r Muller) counter is constructed with locally available components.\r The constructed high voltage unit is based on push-pull mode\r and it is acceptable for low-level primary voltage (2V to 10.19V)\r and delivers it at high-level secondary voltage (105V to 514V) of\r transformer. To avoid the insulation problem at the transformer\r secondary coil, a voltage multiplying circuit is used. The desired\r voltage is rectified and multiplied by voltage multiplier unit\r provides 3055V (-3 kV) DC at approximately 1mA output\r current."}]}, "item_1583103108160": {"attribute_name": "Keywords", "attribute_value_mlt": [{"interim": "high voltage power supply unit"}]}, "item_1583103120197": {"attribute_name": "Files", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2020-05-05"}], "displaytype": "preview", "download_preview_message": "", "file_order": 0, "filename": "28.Construction of High Voltage by Khin Kyu Kyu Hlaing.pdf", "filesize": [{"value": "2361 Kb"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2361000.0, "url": {"url": "https://meral.edu.mm/record/2125/files/28.Construction of High Voltage by Khin Kyu Kyu Hlaing.pdf"}, "version_id": "ecc91de0-2be8-42f9-b9e0-62fd850225f5"}]}, "item_1583103131163": {"attribute_name": "Journal articles", "attribute_value_mlt": [{}]}, "item_1583103147082": {"attribute_name": "Conference papaers", "attribute_value_mlt": [{}]}, "item_1583103211336": {"attribute_name": "Books/reports/chapters", "attribute_value_mlt": [{}]}, "item_1583103233624": {"attribute_name": "Thesis/dissertations", "attribute_value_mlt": [{"subitem_supervisor(s)": []}]}, "item_1583105942107": {"attribute_name": "Authors", "attribute_value_mlt": [{"subitem_authors": [{"subitem_authors_fullname": "Khin Kyu Kyu Hlaing"}, {"subitem_authors_fullname": "Mya Sandi"}]}]}, "item_1583108359239": {"attribute_name": "Upload type", "attribute_value_mlt": [{"interim": "Publication"}]}, "item_1583108428133": {"attribute_name": "Publication type", "attribute_value_mlt": [{"interim": "Conference paper"}]}, "item_1583159729339": {"attribute_name": "Publication date", "attribute_value": "2010"}, "item_1583159847033": {"attribute_name": "Identifier", "attribute_value": "http://uyr.uy.edu.mm/handle/123456789/145"}, "item_title": "Construction of High Voltage Power Supply Unit for GM Counter", "item_type_id": "21", "owner": "1", "path": ["1582967549708"], "permalink_uri": "http://hdl.handle.net/20.500.12678/0000002125", "pubdate": {"attribute_name": "Deposited date", "attribute_value": "2020-03-05"}, "publish_date": "2020-03-05", "publish_status": "0", "recid": "2125", "relation": {}, "relation_version_is_last": true, "title": ["Construction of High Voltage Power Supply Unit for GM Counter"], "weko_shared_id": -1}
  1. University of Yangon
  2. Department of Physics

Construction of High Voltage Power Supply Unit for GM Counter

http://hdl.handle.net/20.500.12678/0000002125
http://hdl.handle.net/20.500.12678/0000002125
958de220-3012-4088-b713-d479cddd6cc5
ca7de646-2731-4629-823b-ef3f89c40f41
None
Preview
Name / File License Actions
28.Construction 28.Construction of High Voltage by Khin Kyu Kyu Hlaing.pdf (2361 Kb)
Publication type
Conference paper
Upload type
Publication
Title
Title Construction of High Voltage Power Supply Unit for GM Counter
Language en
Publication date 2010
Authors
Khin Kyu Kyu Hlaing
Mya Sandi
Description
High Voltage Power Supply Unit is essential for
nuclear radiation detection or counting system. A high voltage
power supply unit that is suitable to use with GM (Geiger
Muller) counter is constructed with locally available components.
The constructed high voltage unit is based on push-pull mode
and it is acceptable for low-level primary voltage (2V to 10.19V)
and delivers it at high-level secondary voltage (105V to 514V) of
transformer. To avoid the insulation problem at the transformer
secondary coil, a voltage multiplying circuit is used. The desired
voltage is rectified and multiplied by voltage multiplier unit
provides 3055V (-3 kV) DC at approximately 1mA output
current.
Keywords
high voltage power supply unit
Identifier http://uyr.uy.edu.mm/handle/123456789/145
Journal articles
Conference papaers
Books/reports/chapters
Thesis/dissertations
Back
0
0
views
downloads
See details
Views Downloads

Versions

Ver.1 2020-03-08 23:26:39.773041
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Export

OAI-PMH
  • OAI-PMH DublinCore
Other Formats
  • JSON

Confirm


Back to MERAL


Back to MERAL