{"_buckets": {"deposit": "ca7de646-2731-4629-823b-ef3f89c40f41"}, "_deposit": {"id": "2125", "owners": [], "pid": {"revision_id": 0, "type": "recid", "value": "2125"}, "status": "published"}, "_oai": {"id": "oai:meral.edu.mm:recid/2125", "sets": ["user-uy"]}, "communities": ["ccm", "ccp", "kyauksetu", "ltc", "maas", "miit", "mlmu", "mmu", "mtlu", "mtu", "mub", "mude", "mufl", "pathein", "scu", "suoe", "tcu", "tgu", "tuh", "tum", "ucsm", "ucsmtla", "ucsmub", "ucspathein", "ucstaungoo", "ucsy", "udmm", "udmy", "uit", "um", "um1", "um2", "umkn", "umm", "uphy", "urj", "uvs", "uy", "yau", "ydbu", "ytu", "yude", "yueco", "yufl", "yuoe"], "control_number": "2125", "item_1583103067471": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Construction of High Voltage Power Supply Unit for GM Counter", "subitem_1551255648112": "en"}]}, "item_1583103085720": {"attribute_name": "Description", "attribute_value_mlt": [{"interim": "High Voltage Power Supply Unit is essential for\r nuclear radiation detection or counting system. A high voltage\r power supply unit that is suitable to use with GM (Geiger\r Muller) counter is constructed with locally available components.\r The constructed high voltage unit is based on push-pull mode\r and it is acceptable for low-level primary voltage (2V to 10.19V)\r and delivers it at high-level secondary voltage (105V to 514V) of\r transformer. To avoid the insulation problem at the transformer\r secondary coil, a voltage multiplying circuit is used. The desired\r voltage is rectified and multiplied by voltage multiplier unit\r provides 3055V (-3 kV) DC at approximately 1mA output\r current."}]}, "item_1583103108160": {"attribute_name": "Keywords", "attribute_value_mlt": [{"interim": "high voltage power supply unit"}]}, "item_1583103120197": {"attribute_name": "Files", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2020-05-05"}], "displaytype": "preview", "download_preview_message": "", "file_order": 0, "filename": "28.Construction of High Voltage by Khin Kyu Kyu Hlaing.pdf", "filesize": [{"value": "2361 Kb"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2361000.0, "url": {"url": "https://meral.edu.mm/record/2125/files/28.Construction of High Voltage by Khin Kyu Kyu Hlaing.pdf"}, "version_id": "ecc91de0-2be8-42f9-b9e0-62fd850225f5"}]}, "item_1583103131163": {"attribute_name": "Journal articles", "attribute_value_mlt": [{}]}, "item_1583103147082": {"attribute_name": "Conference papaers", "attribute_value_mlt": [{}]}, "item_1583103211336": {"attribute_name": "Books/reports/chapters", "attribute_value_mlt": [{}]}, "item_1583103233624": {"attribute_name": "Thesis/dissertations", "attribute_value_mlt": [{"subitem_supervisor(s)": []}]}, "item_1583105942107": {"attribute_name": "Authors", "attribute_value_mlt": [{"subitem_authors": [{"subitem_authors_fullname": "Khin Kyu Kyu Hlaing"}, {"subitem_authors_fullname": "Mya Sandi"}]}]}, "item_1583108359239": {"attribute_name": "Upload type", "attribute_value_mlt": [{"interim": "Publication"}]}, "item_1583108428133": {"attribute_name": "Publication type", "attribute_value_mlt": [{"interim": "Conference paper"}]}, "item_1583159729339": {"attribute_name": "Publication date", "attribute_value": "2010"}, "item_1583159847033": {"attribute_name": "Identifier", "attribute_value": "http://uyr.uy.edu.mm/handle/123456789/145"}, "item_title": "Construction of High Voltage Power Supply Unit for GM Counter", "item_type_id": "21", "owner": "1", "path": ["1582967549708"], "permalink_uri": "http://hdl.handle.net/20.500.12678/0000002125", "pubdate": {"attribute_name": "Deposited date", "attribute_value": "2020-03-05"}, "publish_date": "2020-03-05", "publish_status": "0", "recid": "2125", "relation": {}, "relation_version_is_last": true, "title": ["Construction of High Voltage Power Supply Unit for GM Counter"], "weko_shared_id": -1}
Construction of High Voltage Power Supply Unit for GM Counter
http://hdl.handle.net/20.500.12678/0000002125
http://hdl.handle.net/20.500.12678/0000002125958de220-3012-4088-b713-d479cddd6cc5
ca7de646-2731-4629-823b-ef3f89c40f41
Name / File | License | Actions |
---|---|---|
![]() |
|
Publication type | ||||||
---|---|---|---|---|---|---|
Conference paper | ||||||
Upload type | ||||||
Publication | ||||||
Title | ||||||
Title | Construction of High Voltage Power Supply Unit for GM Counter | |||||
Language | en | |||||
Publication date | 2010 | |||||
Authors | ||||||
Khin Kyu Kyu Hlaing | ||||||
Mya Sandi | ||||||
Description | ||||||
High Voltage Power Supply Unit is essential for nuclear radiation detection or counting system. A high voltage power supply unit that is suitable to use with GM (Geiger Muller) counter is constructed with locally available components. The constructed high voltage unit is based on push-pull mode and it is acceptable for low-level primary voltage (2V to 10.19V) and delivers it at high-level secondary voltage (105V to 514V) of transformer. To avoid the insulation problem at the transformer secondary coil, a voltage multiplying circuit is used. The desired voltage is rectified and multiplied by voltage multiplier unit provides 3055V (-3 kV) DC at approximately 1mA output current. |
||||||
Keywords | ||||||
high voltage power supply unit | ||||||
Identifier | http://uyr.uy.edu.mm/handle/123456789/145 | |||||