MERAL Myanmar Education Research and Learning Portal
Item
{"_buckets": {"deposit": "52ab843a-b40c-4843-9254-26fa7462129e"}, "_deposit": {"created_by": 155, "id": "7627", "owner": "155", "owners": [155], "owners_ext": {"displayname": "", "username": ""}, "pid": {"revision_id": 0, "type": "depid", "value": "7627"}, "status": "published"}, "_oai": {"id": "oai:meral.edu.mm:recid/00007627", "sets": ["user-mmu"]}, "communities": ["mmu"], "item_1583103067471": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "TRANSIENT BOILING CRITICAL HEAT FLUX ON HORIZONTAL VERTICALLY-ORIENTED RIBBON IN A POOL OF WATER", "subitem_1551255648112": "en"}]}, "item_1583103085720": {"attribute_name": "Description", "attribute_value_mlt": [{"interim": "ABSTRACT The deep understanding for transient pool boiling CHF phenomena and its correlation in water are becoming increasingly important as the fundamental database for the design of liquid cooling technologies. Transient critical heat flux (CHF) due to exponentially increasing heat inputs to a platinum ribbon in a pool of water were measured for subcoolings near atmospheric pressures. The exponential heat generation period was varied from 10 ms to 20 s. The horizontal vertically-oriented ribbon as a test heater was installed in boiling vessel. The values of contact angle and surface roughness were also measured in advance before pool boiling experiment. The heat transfer processes at surface superheats are compared with previous correlations on the effect of contact angle, surface condition and so on."}]}, "item_1583103108160": {"attribute_name": "Keywords", "attribute_value_mlt": [{"interim": "transient CHF, horizontal vertically-oriented ribbon, contact angle, surface condition"}]}, "item_1583103120197": {"attribute_name": "Files", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "displaytype": "preview", "download_preview_message": "", "file_order": 0, "filename": "", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_0", "mimetype": "", "size": 0, "version_id": ""}]}, "item_1583103147082": {"attribute_name": "Conference papers", "attribute_value_mlt": [{"subitem_acronym": "Proceedings of the International Symposium on Marine Engineering", "subitem_c_date": "September 15-19, 2014", "subitem_conference_title": "International Symposium on Marine Engineering(ISME) ,", "subitem_place": "Harbin, China"}]}, "item_1583105942107": {"attribute_name": "Authors", "attribute_value_mlt": [{"subitem_authors": [{"subitem_authors_fullname": "Min Han Htet"}]}]}, "item_1583108359239": {"attribute_name": "Upload type", "attribute_value_mlt": [{"interim": "Publication"}]}, "item_1583108428133": {"attribute_name": "Publication type", "attribute_value_mlt": [{"interim": "Conference paper"}]}, "item_1583159729339": {"attribute_name": "Publication date", "attribute_value": "2014-09-14"}, "item_title": "TRANSIENT BOILING CRITICAL HEAT FLUX ON HORIZONTAL VERTICALLY-ORIENTED RIBBON IN A POOL OF WATER", "item_type_id": "21", "owner": "155", "path": ["1608152094107"], "permalink_uri": "http://hdl.handle.net/20.500.12678/0000007627", "pubdate": {"attribute_name": "Deposited date", "attribute_value": "2021-01-19"}, "publish_date": "2021-01-19", "publish_status": "0", "recid": "7627", "relation": {}, "relation_version_is_last": true, "title": ["TRANSIENT BOILING CRITICAL HEAT FLUX ON HORIZONTAL VERTICALLY-ORIENTED RIBBON IN A POOL OF WATER"], "weko_shared_id": -1}
TRANSIENT BOILING CRITICAL HEAT FLUX ON HORIZONTAL VERTICALLY-ORIENTED RIBBON IN A POOL OF WATER
http://hdl.handle.net/20.500.12678/0000007627
http://hdl.handle.net/20.500.12678/0000007627b749ce0a-13df-47d9-88f6-70e28ff423fe
52ab843a-b40c-4843-9254-26fa7462129e
Name / File | License | Actions |
---|---|---|
![]() |
Publication type | ||||||
---|---|---|---|---|---|---|
Conference paper | ||||||
Upload type | ||||||
Publication | ||||||
Title | ||||||
Title | TRANSIENT BOILING CRITICAL HEAT FLUX ON HORIZONTAL VERTICALLY-ORIENTED RIBBON IN A POOL OF WATER | |||||
Language | en | |||||
Publication date | 2014-09-14 | |||||
Authors | ||||||
Min Han Htet | ||||||
Description | ||||||
ABSTRACT The deep understanding for transient pool boiling CHF phenomena and its correlation in water are becoming increasingly important as the fundamental database for the design of liquid cooling technologies. Transient critical heat flux (CHF) due to exponentially increasing heat inputs to a platinum ribbon in a pool of water were measured for subcoolings near atmospheric pressures. The exponential heat generation period was varied from 10 ms to 20 s. The horizontal vertically-oriented ribbon as a test heater was installed in boiling vessel. The values of contact angle and surface roughness were also measured in advance before pool boiling experiment. The heat transfer processes at surface superheats are compared with previous correlations on the effect of contact angle, surface condition and so on. | ||||||
Keywords | ||||||
transient CHF, horizontal vertically-oriented ribbon, contact angle, surface condition | ||||||
Conference papers | ||||||
Proceedings of the International Symposium on Marine Engineering | ||||||
September 15-19, 2014 | ||||||
International Symposium on Marine Engineering(ISME) , | ||||||
Harbin, China |