Log in
Language:

MERAL Myanmar Education Research and Learning Portal

  • MERAL
  • Universities
  • Ranking
AND
To


Index Link

Index Tree

WEKO

One fine body…

Item

{"_buckets": {"deposit": "5cfa6cd6-befc-40a1-9077-042d4acb056e"}, "_deposit": {"created_by": 23, "id": "5162", "owner": "23", "owners": [23], "owners_ext": {"displayname": "", "email": "myanila@mu.edu.mm", "username": ""}, "pid": {"revision_id": 0, "type": "recid", "value": "5162"}, "status": "published"}, "_oai": {"id": "oai:meral.edu.mm:recid/5162"}, "control_number": "5162", "item_1583103067471": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Analysis on Gamma Spectra by NaI (Tl) Detector", "subitem_1551255648112": "en"}]}, "item_1583103085720": {"attribute_name": "Description", "attribute_value_mlt": [{"interim": "The (3\u0027\u0027 x 3\u0027\u0027) NaI (Tl) detector at the Experimental Nuclear Laboratory, Physics Department, Mandalay University was used for gamma spectrum analysis incorporation with Gamma Vision 32 software. The standard gamma source 152Eu (Spectrum Technique, USA) was used to calibrate the NaI (Tl) detector. Calibration range was 122 keV to 1408 keV and showed a linear relation of 0.943 keV per channel. Sand sample from Moemauk Hot Spring, Banmaw Township, Kachin State was analyzed by gamma spectroscopy. The gamma emissions were observed at 212Pb (239 keV), 228Ac (338 keV), 208Tl (583 keV), 228Ac (911 keV) and 40K (1460 keV). With high resolution detector, such as HpGe, more gamma emissions were expected to be observed."}]}, "item_1583103108160": {"attribute_name": "Keywords", "attribute_value_mlt": [{"interim": "Gamma Spectrum Analysis"}, {"interim": "Energy Calibration"}, {"interim": "Gamma Emissions"}]}, "item_1583103120197": {"attribute_name": "Files", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2020-09-03"}], "displaytype": "preview", "download_preview_message": "", "filename": "Analysis on Gamma Spectra by NaI (Tl) Detector.pdf", "filesize": [{"value": "290 Kb"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_0", "mimetype": "application/pdf", "size": 290000, "url": {"url": "https://meral.edu.mm/record/5162/files/Analysis on Gamma Spectra by NaI (Tl) Detector.pdf"}, "version_id": "ffcd9636-5931-47db-a54f-55c5e5c1d5d0"}]}, "item_1583103147082": {"attribute_name": "Conference papers", "attribute_value_mlt": [{"subitem_acronym": "ICPM", "subitem_c_date": "25-27 November 2018", "subitem_conference_title": "International Conference on Physics, Mandalay", "subitem_place": "University of Mandalay"}]}, "item_1583105942107": {"attribute_name": "Authors", "attribute_value_mlt": [{"subitem_authors": [{"subitem_authors_fullname": "Shin Thant Lwan Maung"}, {"subitem_authors_fullname": "Kay Khaing Oo"}]}]}, "item_1583108359239": {"attribute_name": "Upload type", "attribute_name_i18n": "Upload type", "attribute_value": "Publication"}, "item_1583108428133": {"attribute_name": "Publication type", "attribute_name_i18n": "Publication type", "attribute_value": "Conference paper"}, "item_1583159729339": {"attribute_name": "Publication date", "attribute_name_i18n": "Publication date", "attribute_value": "2018-11-27"}, "item_title": "Analysis on Gamma Spectra by NaI (Tl) Detector", "item_type_id": "21", "owner": "23", "path": ["1582963739756", "1582963739756/1582967025340"], "permalink_uri": "http://hdl.handle.net/20.500.12678/0000005162", "pubdate": {"attribute_name": "Deposited date", "attribute_value": "2020-09-03"}, "publish_date": "2020-09-03", "publish_status": "0", "recid": "5162", "relation": {}, "relation_version_is_last": true, "title": ["Analysis on Gamma Spectra by NaI (Tl) Detector"], "weko_shared_id": -1}
  1. University of Mandalay
  1. University of Mandalay
  2. Department of Physics

Analysis on Gamma Spectra by NaI (Tl) Detector

http://hdl.handle.net/20.500.12678/0000005162
36c70546-c0dd-4670-b5d5-283f14bc3873
5cfa6cd6-befc-40a1-9077-042d4acb056e
Preview
Name / File License Actions
Analysis Analysis on Gamma Spectra by NaI (Tl) Detector.pdf (290 Kb)
license.icon
Publication type Conference paper
Upload type Publication
Title
Analysis on Gamma Spectra by NaI (Tl) Detector
en
Publication date 2018-11-27
Authors
Shin Thant Lwan Maung
Kay Khaing Oo
Description
The (3'' x 3'') NaI (Tl) detector at the Experimental Nuclear Laboratory, Physics Department, Mandalay University was used for gamma spectrum analysis incorporation with Gamma Vision 32 software. The standard gamma source 152Eu (Spectrum Technique, USA) was used to calibrate the NaI (Tl) detector. Calibration range was 122 keV to 1408 keV and showed a linear relation of 0.943 keV per channel. Sand sample from Moemauk Hot Spring, Banmaw Township, Kachin State was analyzed by gamma spectroscopy. The gamma emissions were observed at 212Pb (239 keV), 228Ac (338 keV), 208Tl (583 keV), 228Ac (911 keV) and 40K (1460 keV). With high resolution detector, such as HpGe, more gamma emissions were expected to be observed.
Keywords
Gamma Spectrum Analysis
Keywords
Energy Calibration
Keywords
Gamma Emissions
Conference papers
ICPM
25-27 November 2018
International Conference on Physics, Mandalay
University of Mandalay
Back
0
0
views
downloads
See details
Views Downloads

Versions

Ver.2 2020-09-04 04:59:36.485584
Ver.1 2020-09-03 06:51:34.018654
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Export

OAI-PMH
  • OAI-PMH DublinCore
Other Formats
  • JSON

Confirm


Back to MERAL


Back to MERAL