{"_buckets": {"deposit": "485a3db0-3e61-4843-9d27-aa4ca138e4a9"}, "_deposit": {"id": "380", "owners": [], "pid": {"revision_id": 0, "type": "recid", "value": "380"}, "status": "published"}, "_oai": {"id": "oai:meral.edu.mm:recid/380", "sets": ["user-ydbu"]}, "communities": ["ydbu"], "control_number": "380", "item_1583103067471": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Analysis on spatial distribution of fire stations in Chanayethazan Township", "subitem_1551255648112": "en"}]}, "item_1583103085720": {"attribute_name": "Description", "attribute_value_mlt": [{"interim": "This research attempts to analyze the spatial distribution of fire stations in Chanayethazan\r Township. The main aim of this research is to evaluate whether the number of fire stations are\r sufficient for the protection of the outbreaks of the fire or not in the wards of the\r Chanayethazan Township. The spatial distribution of fire stations are analyzed by using Hot\r Spot Analysis adopted by Getis-Ord Getis and Multi Ring Buffer with the aid of Geographic\r Information System (GIS). It is found that the housing types and inadequate water are\r important for fire prevention in the township. Seittaramahi, Thirihaymar (West),\r Pyigyipyawpwe (West), Dewun (West) are danger zones with fire precaution because of the\r largest number of houses, unsystematic road system and inflammable materials. To avoid the\r fire outbreaks, systematic utilization of land is essential in Chanayethazan Township."}]}, "item_1583103108160": {"attribute_name": "Keywords", "attribute_value_mlt": [{"interim": "outbreaks"}]}, "item_1583103120197": {"attribute_name": "Files", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2020-05-05"}], "displaytype": "preview", "download_preview_message": "", "file_order": 0, "filename": "San SanNwe, Yi Yi Tint,.pdf", "filesize": [{"value": "538 Kb"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 538000.0, "url": {"url": "https://meral.edu.mm/record/380/files/San SanNwe, Yi Yi Tint,.pdf"}, "version_id": "ccbedab9-512f-40c9-bf48-81d021d028fb"}]}, "item_1583103131163": {"attribute_name": "Journal articles", "attribute_value_mlt": [{"subitem_issue": "1", "subitem_journal_title": "Yadanabon University Research Journal", "subitem_volume": "9"}]}, "item_1583103147082": {"attribute_name": "Conference papaers", "attribute_value_mlt": [{}]}, "item_1583103211336": {"attribute_name": "Books/reports/chapters", "attribute_value_mlt": [{}]}, "item_1583103233624": {"attribute_name": "Thesis/dissertations", "attribute_value_mlt": [{"subitem_supervisor(s)": []}]}, "item_1583105942107": {"attribute_name": "Authors", "attribute_value_mlt": [{"subitem_authors": [{"subitem_authors_fullname": "San San Nwe"}, {"subitem_authors_fullname": "Yi Yi Tint"}, {"subitem_authors_fullname": "Khin Thaw Tar"}, {"subitem_authors_fullname": "Hla Myint"}]}]}, "item_1583108359239": {"attribute_name": "Upload type", "attribute_value_mlt": [{"interim": "Publication"}]}, "item_1583108428133": {"attribute_name": "Publication type", "attribute_value_mlt": [{"interim": "Journal article"}]}, "item_1583159729339": {"attribute_name": "Publication date", "attribute_value": "2018"}, "item_1583159847033": {"attribute_name": "Identifier", "attribute_value": "https://oar.ydbu.edu.mm/handle/123456789/247"}, "item_title": "Analysis on spatial distribution of fire stations in Chanayethazan Township", "item_type_id": "21", "owner": "1", "path": ["1582966223276"], "permalink_uri": "http://hdl.handle.net/20.500.12678/0000000380", "pubdate": {"attribute_name": "Deposited date", "attribute_value": "2020-03-05"}, "publish_date": "2020-03-05", "publish_status": "0", "recid": "380", "relation": {}, "relation_version_is_last": true, "title": ["Analysis on spatial distribution of fire stations in Chanayethazan Township"], "weko_shared_id": -1}
Analysis on spatial distribution of fire stations in Chanayethazan Township
http://hdl.handle.net/20.500.12678/0000000380
http://hdl.handle.net/20.500.12678/0000000380195d7f74-0523-40b7-8aea-7f697e97cea9
485a3db0-3e61-4843-9d27-aa4ca138e4a9
Name / File | License | Actions |
---|---|---|
San SanNwe, Yi Yi Tint,.pdf (538 Kb)
|
|
Publication type | ||||||
---|---|---|---|---|---|---|
Journal article | ||||||
Upload type | ||||||
Publication | ||||||
Title | ||||||
Title | Analysis on spatial distribution of fire stations in Chanayethazan Township | |||||
Language | en | |||||
Publication date | 2018 | |||||
Authors | ||||||
San San Nwe | ||||||
Yi Yi Tint | ||||||
Khin Thaw Tar | ||||||
Hla Myint | ||||||
Description | ||||||
This research attempts to analyze the spatial distribution of fire stations in Chanayethazan Township. The main aim of this research is to evaluate whether the number of fire stations are sufficient for the protection of the outbreaks of the fire or not in the wards of the Chanayethazan Township. The spatial distribution of fire stations are analyzed by using Hot Spot Analysis adopted by Getis-Ord Getis and Multi Ring Buffer with the aid of Geographic Information System (GIS). It is found that the housing types and inadequate water are important for fire prevention in the township. Seittaramahi, Thirihaymar (West), Pyigyipyawpwe (West), Dewun (West) are danger zones with fire precaution because of the largest number of houses, unsystematic road system and inflammable materials. To avoid the fire outbreaks, systematic utilization of land is essential in Chanayethazan Township. |
||||||
Keywords | ||||||
outbreaks | ||||||
Identifier | https://oar.ydbu.edu.mm/handle/123456789/247 | |||||
Journal articles | ||||||
1 | ||||||
Yadanabon University Research Journal | ||||||
9 | ||||||
Conference papaers | ||||||
Books/reports/chapters | ||||||
Thesis/dissertations |