{"_buckets": {"deposit": "b1b21d00-3979-41fd-942e-d4e32b6cb8e2"}, "_deposit": {"id": "2695", "owners": [], "pid": {"revision_id": 0, "type": "recid", "value": "2695"}, "status": "published"}, "_oai": {"id": "oai:meral.edu.mm:recid/2695", "sets": ["user-uy"]}, "communities": ["ccm", "ccp", "kyauksetu", "ltc", "maas", "miit", "mlmu", "mmu", "mtlu", "mtu", "mub", "mude", "mufl", "pathein", "scu", "suoe", "tcu", "tgu", "tuh", "tum", "ucsm", "ucsmtla", "ucsmub", "ucspathein", "ucstaungoo", "ucsy", "udmm", "udmy", "uit", "um", "um1", "um2", "umkn", "umm", "uphy", "urj", "uvs", "uy", "yau", "ydbu", "ytu", "yude", "yueco", "yufl", "yuoe"], "control_number": "2695", "item_1583103067471": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Design and Analysis of Three-phase 230 kV Transmission Line in the North-East of Myanmar", "subitem_1551255648112": "en"}]}, "item_1583103085720": {"attribute_name": "Description", "attribute_value_mlt": [{"interim": "Long transmission lines are required to transmit power from hydroelectric power stations to the places of load, as the sites of water power would be far away from the load centers. In this paper, it designed and analyzed three-phase 230 kV transmission line for the North-East of Myanmar. Shweli hydroelectric power station generates the power of 90 MW for Shweli-Mandalay (Shwe Sar Yan) transmission line portion. The length of the transmission line from Shweli to Shwe Sar Yan is 287.93 km. It aims to distribute electricity to Lashio and Kyaukme districts, Northern Shan State and to transport electricity to Mandalay (Shwe Sar Yan) by using 230 kV Twin Bundle Double Circuit transmission line. The purpose of this paper is to transmit optimum power at a given power factor, over a given distance and regulation, efficiency and losses."}]}, "item_1583103108160": {"attribute_name": "Keywords", "attribute_value_mlt": [{"interim": "electrical design"}]}, "item_1583103120197": {"attribute_name": "Files", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2020-05-05"}], "displaytype": "preview", "download_preview_message": "", "file_order": 0, "filename": "Design and analysis of three-phase 230 kV transmission line in the North-East of Myanmar.pdf", "filesize": [{"value": "1772 Kb"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1772000.0, "url": {"url": "https://meral.edu.mm/record/2695/files/Design and analysis of three-phase 230 kV transmission line in the North-East of Myanmar.pdf"}, "version_id": "46102018-5bb7-48ba-915d-ed75fbb1d1d6"}]}, "item_1583103131163": {"attribute_name": "Journal articles", "attribute_value_mlt": [{"subitem_journal_title": "Proceedings of the First International Conference on Science and Engineering", "subitem_volume": "1"}]}, "item_1583103147082": {"attribute_name": "Conference papaers", "attribute_value_mlt": [{}]}, "item_1583103211336": {"attribute_name": "Books/reports/chapters", "attribute_value_mlt": [{}]}, "item_1583103233624": {"attribute_name": "Thesis/dissertations", "attribute_value_mlt": [{"subitem_supervisor(s)": []}]}, "item_1583105942107": {"attribute_name": "Authors", "attribute_value_mlt": [{"subitem_authors": [{"subitem_authors_fullname": "Zar Kyi Win"}]}]}, "item_1583108359239": {"attribute_name": "Upload type", "attribute_value_mlt": [{"interim": "Other"}]}, "item_1583108428133": {"attribute_name": "Publication type", "attribute_value_mlt": [{"interim": "Other"}]}, "item_1583159729339": {"attribute_name": "Publication date", "attribute_value": "2009"}, "item_1583159847033": {"attribute_name": "Identifier", "attribute_value": "https://uyr.uy.edu.mm/handle/123456789/333"}, "item_title": "Design and Analysis of Three-phase 230 kV Transmission Line in the North-East of Myanmar", "item_type_id": "21", "owner": "1", "path": ["1582967549708"], "permalink_uri": "http://hdl.handle.net/20.500.12678/0000002695", "pubdate": {"attribute_name": "Deposited date", "attribute_value": "2020-03-05"}, "publish_date": "2020-03-05", "publish_status": "0", "recid": "2695", "relation": {}, "relation_version_is_last": true, "title": ["Design and Analysis of Three-phase 230 kV Transmission Line in the North-East of Myanmar"], "weko_shared_id": -1}
  1. University of Yangon
  2. Department of Physics

Design and Analysis of Three-phase 230 kV Transmission Line in the North-East of Myanmar

http://hdl.handle.net/20.500.12678/0000002695
http://hdl.handle.net/20.500.12678/0000002695
3d10359e-d7d4-4f64-ae33-5fd9daa9b953
b1b21d00-3979-41fd-942e-d4e32b6cb8e2
None
Preview
Name / File License Actions
Design Design and analysis of three-phase 230 kV transmission line in the North-East of Myanmar.pdf (1772 Kb)
Publication type
Other
Upload type
Other
Title
Title Design and Analysis of Three-phase 230 kV Transmission Line in the North-East of Myanmar
Language en
Publication date 2009
Authors
Zar Kyi Win
Description
Long transmission lines are required to transmit power from hydroelectric power stations to the places of load, as the sites of water power would be far away from the load centers. In this paper, it designed and analyzed three-phase 230 kV transmission line for the North-East of Myanmar. Shweli hydroelectric power station generates the power of 90 MW for Shweli-Mandalay (Shwe Sar Yan) transmission line portion. The length of the transmission line from Shweli to Shwe Sar Yan is 287.93 km. It aims to distribute electricity to Lashio and Kyaukme districts, Northern Shan State and to transport electricity to Mandalay (Shwe Sar Yan) by using 230 kV Twin Bundle Double Circuit transmission line. The purpose of this paper is to transmit optimum power at a given power factor, over a given distance and regulation, efficiency and losses.
Keywords
electrical design
Identifier https://uyr.uy.edu.mm/handle/123456789/333
Journal articles
Proceedings of the First International Conference on Science and Engineering
1
Conference papaers
Books/reports/chapters
Thesis/dissertations
Back
0
0
views
downloads
See details
Views Downloads

Versions

Ver.1 2020-03-08 23:47:23.681963
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Export

OAI-PMH
  • OAI-PMH DublinCore
Other Formats
  • JSON

Confirm


Back to MERAL


Back to MERAL