{"_buckets": {"deposit": "833d8e51-0652-4322-80ba-854003bbfd55"}, "_deposit": {"id": "2562", "owners": [], "pid": {"revision_id": 0, "type": "recid", "value": "2562"}, "status": "published"}, "_oai": {"id": "oai:meral.edu.mm:recid/2562", "sets": ["user-uy"]}, "communities": ["ccm", "ccp", "kyauksetu", "ltc", "maas", "miit", "mlmu", "mmu", "mtlu", "mtu", "mub", "mude", "mufl", "pathein", "scu", "suoe", "tcu", "tgu", "tuh", "tum", "ucsm", "ucsmtla", "ucsmub", "ucspathein", "ucstaungoo", "ucsy", "udmm", "udmy", "uit", "um", "um1", "um2", "umkn", "umm", "uphy", "urj", "uvs", "uy", "yau", "ydbu", "ytu", "yude", "yueco", "yufl", "yuoe"], "control_number": "2562", "item_1583103067471": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Determination Short Circuit fault and Unbalance Voltage Source of Induction Motor Using Park Vector Modulus and Wavelet Transform", "subitem_1551255648112": "en"}]}, "item_1583103085720": {"attribute_name": "Description", "attribute_value_mlt": [{"interim": "In this study, winding short circuit fault and unbalance voltage source in induction motor are detected. Stator current is recorded and converted into a Park\u0027s Vector Modulus (PVM) signal. PVM signal is then processed using the Discrete Wavelet Transform (DWT). Power Details Density (PDD) signal of wavelet transform is used to detect disturbances that occur in stator. The result shows that the proposed method is able to detect short circuit fault andunbalance voltage source. Winding short circuit is detected as higher value of PDD level Dl, D2 and D3, while unbalanced voltage source is detected from D6, D7 and D8."}]}, "item_1583103108160": {"attribute_name": "Keywords", "attribute_value_mlt": [{"interim": "Short Circuit fault"}]}, "item_1583103120197": {"attribute_name": "Files", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2020-05-05"}], "displaytype": "preview", "download_preview_message": "", "file_order": 0, "filename": "Determination short circuit fault and unbalance voltage source of induction motor using park vector modules and wavelet transform.pdf", "filesize": [{"value": "1210 Kb"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1210000.0, "url": {"url": "https://meral.edu.mm/record/2562/files/Determination short circuit fault and unbalance voltage source of induction motor using park vector modules and wavelet transform.pdf"}, "version_id": "67eaf826-c2e8-4f3a-ac87-9f62e550a479"}]}, "item_1583103131163": {"attribute_name": "Journal articles", "attribute_value_mlt": [{"subitem_journal_title": "8th AUN/SEED-Net Regional Conference on Electrical and Electronics Engineering"}]}, "item_1583103147082": {"attribute_name": "Conference papaers", "attribute_value_mlt": [{}]}, "item_1583103211336": {"attribute_name": "Books/reports/chapters", "attribute_value_mlt": [{}]}, "item_1583103233624": {"attribute_name": "Thesis/dissertations", "attribute_value_mlt": [{"subitem_supervisor(s)": []}]}, "item_1583105942107": {"attribute_name": "Authors", "attribute_value_mlt": [{"subitem_authors": [{"subitem_authors_fullname": "Asfani, Dimas Anton"}, {"subitem_authors_fullname": "Ariyani, Fitri"}, {"subitem_authors_fullname": "Negera, I Made Yulistya"}, {"subitem_authors_fullname": "Fahmi, Daniar"}, {"subitem_authors_fullname": "Wahyudi, R."}]}]}, "item_1583108359239": {"attribute_name": "Upload type", "attribute_value_mlt": [{"interim": "Other"}]}, "item_1583108428133": {"attribute_name": "Publication type", "attribute_value_mlt": [{"interim": "Other"}]}, "item_1583159729339": {"attribute_name": "Publication date", "attribute_value": "2015"}, "item_1583159847033": {"attribute_name": "Identifier", "attribute_value": "https://uyr.uy.edu.mm/handle/123456789/457"}, "item_title": "Determination Short Circuit fault and Unbalance Voltage Source of Induction Motor Using Park Vector Modulus and Wavelet Transform", "item_type_id": "21", "owner": "1", "path": ["1582967549708"], "permalink_uri": "http://hdl.handle.net/20.500.12678/0000002562", "pubdate": {"attribute_name": "Deposited date", "attribute_value": "2020-03-05"}, "publish_date": "2020-03-05", "publish_status": "0", "recid": "2562", "relation": {}, "relation_version_is_last": true, "title": ["Determination Short Circuit fault and Unbalance Voltage Source of Induction Motor Using Park Vector Modulus and Wavelet Transform"], "weko_shared_id": -1}
Determination Short Circuit fault and Unbalance Voltage Source of Induction Motor Using Park Vector Modulus and Wavelet Transform
http://hdl.handle.net/20.500.12678/0000002562
http://hdl.handle.net/20.500.12678/0000002562038a9082-6881-4c59-98eb-b161a530e520
833d8e51-0652-4322-80ba-854003bbfd55
Name / File | License | Actions |
---|---|---|
Determination short circuit fault and unbalance voltage source of induction motor using park vector modules and wavelet transform.pdf (1210 Kb)
|
|
Publication type | ||||||
---|---|---|---|---|---|---|
Other | ||||||
Upload type | ||||||
Other | ||||||
Title | ||||||
Title | Determination Short Circuit fault and Unbalance Voltage Source of Induction Motor Using Park Vector Modulus and Wavelet Transform | |||||
Language | en | |||||
Publication date | 2015 | |||||
Authors | ||||||
Asfani, Dimas Anton | ||||||
Ariyani, Fitri | ||||||
Negera, I Made Yulistya | ||||||
Fahmi, Daniar | ||||||
Wahyudi, R. | ||||||
Description | ||||||
In this study, winding short circuit fault and unbalance voltage source in induction motor are detected. Stator current is recorded and converted into a Park's Vector Modulus (PVM) signal. PVM signal is then processed using the Discrete Wavelet Transform (DWT). Power Details Density (PDD) signal of wavelet transform is used to detect disturbances that occur in stator. The result shows that the proposed method is able to detect short circuit fault andunbalance voltage source. Winding short circuit is detected as higher value of PDD level Dl, D2 and D3, while unbalanced voltage source is detected from D6, D7 and D8. | ||||||