Index Link

  • RootNode

Item

{"_buckets": {"deposit": "eed2731f-e821-45a2-be9f-b4028095b4b8"}, "_deposit": {"id": "2004", "owners": [], "pid": {"revision_id": 0, "type": "recid", "value": "2004"}, "status": "published"}, "_oai": {"id": "oai:meral.edu.mm:recid/2004", "sets": ["user-uy"]}, "communities": ["ccm", "ccp", "kyauksetu", "ltc", "maas", "miit", "mlmu", "mmu", "mtlu", "mtu", "mub", "mude", "mufl", "pathein", "scu", "suoe", "tcu", "tgu", "tuh", "tum", "ucsm", "ucsmtla", "ucsmub", "ucspathein", "ucstaungoo", "ucsy", "udmm", "udmy", "uit", "um", "um1", "um2", "umkn", "umm", "uphy", "urj", "uvs", "uy", "yau", "ydbu", "ytu", "yude", "yueco", "yufl", "yuoe"], "control_number": "2004", "item_1583103067471": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Impact of Protection System on Distribution System Reliability", "subitem_1551255648112": "en"}]}, "item_1583103085720": {"attribute_name": "Description", "attribute_value_mlt": [{"interim": "Modern society generally expects high reliability power supply. Electricity interruption may cause high damage to consumers. Most of load interruptions are due to breakdowns in distribution systems. Therefore, the improvement of reliability for a di distribution system including its protection system is of interest in this paper. Equipment failure may occur electricity interruption. However with a proper protection system, the interruption will be confined in a particular area resulting in better reliability performance, In this paper , impact of protective devices installation, e.g. disconnecting g switch and fuse on distribution system reliability will be analyzed. In addition, impact of voltage dip on each interested load point will also be calculated and presented. The developed method has been tested with the Reliability Test System (RBTS) [21]."}]}, "item_1583103108160": {"attribute_name": "Keywords", "attribute_value_mlt": [{"interim": "impact of protection"}]}, "item_1583103120197": {"attribute_name": "Files", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2020-05-05"}], "displaytype": "preview", "download_preview_message": "", "file_order": 0, "filename": "Impact of protection system on distribution system reliability.pdf", "filesize": [{"value": "1838 Kb"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1838000.0, "url": {"url": "https://meral.edu.mm/record/2004/files/Impact of protection system on distribution system reliability.pdf"}, "version_id": "f43c9d0a-b9eb-4f15-a344-1b2aafca0c9a"}]}, "item_1583103131163": {"attribute_name": "Journal articles", "attribute_value_mlt": [{"subitem_journal_title": "Proceedings of the First International Conference on Science and Engineering", "subitem_volume": "1"}]}, "item_1583103147082": {"attribute_name": "Conference papaers", "attribute_value_mlt": [{}]}, "item_1583103211336": {"attribute_name": "Books/reports/chapters", "attribute_value_mlt": [{}]}, "item_1583103233624": {"attribute_name": "Thesis/dissertations", "attribute_value_mlt": [{"subitem_supervisor(s)": []}]}, "item_1583105942107": {"attribute_name": "Authors", "attribute_value_mlt": [{"subitem_authors": [{"subitem_authors_fullname": "Ohn Zin Lin"}, {"subitem_authors_fullname": "Bundhit Eua - Arpom"}]}]}, "item_1583108359239": {"attribute_name": "Upload type", "attribute_value_mlt": [{"interim": "Other"}]}, "item_1583108428133": {"attribute_name": "Publication type", "attribute_value_mlt": [{"interim": "Other"}]}, "item_1583159729339": {"attribute_name": "Publication date", "attribute_value": "2009"}, "item_1583159847033": {"attribute_name": "Identifier", "attribute_value": "https://uyr.uy.edu.mm/handle/123456789/326"}, "item_title": "Impact of Protection System on Distribution System Reliability", "item_type_id": "21", "owner": "1", "path": ["1582967549708"], "permalink_uri": "http://hdl.handle.net/20.500.12678/0000002004", "pubdate": {"attribute_name": "Deposited date", "attribute_value": "2020-03-05"}, "publish_date": "2020-03-05", "publish_status": "0", "recid": "2004", "relation": {}, "relation_version_is_last": true, "title": ["Impact of Protection System on Distribution System Reliability"], "weko_shared_id": -1}

Impact of Protection System on Distribution System Reliability

http://hdl.handle.net/20.500.12678/0000002004
14dfd875-198a-45e3-8814-09e59403cb53
eed2731f-e821-45a2-be9f-b4028095b4b8
None
Name / File License Actions
Impact Impact of protection system on distribution system reliability.pdf (1838 Kb)
Publication type
Other
Upload type
Other
Title
Title Impact of Protection System on Distribution System Reliability
Language en
Publication date 2009
Authors
Ohn Zin Lin
Bundhit Eua - Arpom
Description
Modern society generally expects high reliability power supply. Electricity interruption may cause high damage to consumers. Most of load interruptions are due to breakdowns in distribution systems. Therefore, the improvement of reliability for a di distribution system including its protection system is of interest in this paper. Equipment failure may occur electricity interruption. However with a proper protection system, the interruption will be confined in a particular area resulting in better reliability performance, In this paper , impact of protective devices installation, e.g. disconnecting g switch and fuse on distribution system reliability will be analyzed. In addition, impact of voltage dip on each interested load point will also be calculated and presented. The developed method has been tested with the Reliability Test System (RBTS) [21].
Keywords
impact of protection
Identifier https://uyr.uy.edu.mm/handle/123456789/326
Journal articles
Proceedings of the First International Conference on Science and Engineering
1
Conference papaers
Books/reports/chapters
Thesis/dissertations
0
0
views
downloads
Views Downloads

Export

OAI-PMH
  • OAI-PMH DublinCore
Other Formats