MERAL Myanmar Education Research and Learning Portal
Item
{"_buckets": {"deposit": "e9b4912a-afeb-4bfd-996c-e1365aba45a0"}, "_deposit": {"id": "1792", "owners": [], "pid": {"revision_id": 0, "type": "recid", "value": "1792"}, "status": "published"}, "_oai": {"id": "oai:meral.edu.mm:recid/1792", "sets": ["user-uy"]}, "communities": ["ccm", "ccp", "kyauksetu", "ltc", "maas", "miit", "mlmu", "mmu", "mtlu", "mtu", "mub", "mude", "mufl", "pathein", "scu", "suoe", "tcu", "tgu", "tuh", "tum", "ucsm", "ucsmtla", "ucsmub", "ucspathein", "ucstaungoo", "ucsy", "udmm", "udmy", "uit", "um", "um1", "um2", "umkn", "umm", "uphy", "urj", "uvs", "uy", "yau", "ydbu", "ytu", "yude", "yueco", "yufl", "yuoe"], "control_number": "1792", "item_1583103067471": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "Estimation of Uncertainty in Measurement of AC Power", "subitem_1551255648112": "en"}]}, "item_1583103085720": {"attribute_name": "Description", "attribute_value_mlt": [{"interim": "The problem on measurement of AC power in single phase or three-phase networks is always very important. In this paper Test Method is to be applied to Unit Under Test (UUT) Meter which is compared by the known error of Standard Power Meter as reference. This method used to measure the error ofUUT Meter. When estimating the uncertainty of measurement, all components which are of importance in the given situation shall be taken into account using appropriate methods of analysis. In this paper calibration procedure is provided for calibration process of single phase AC power meter using comparison method with its capability as declared. A method for calibration of AC power meter, measurement instruments used in the procedure, processing and presentation of the final results are presented as well."}]}, "item_1583103108160": {"attribute_name": "Keywords", "attribute_value_mlt": [{"interim": "measurement"}]}, "item_1583103120197": {"attribute_name": "Files", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_access", "date": [{"dateType": "Available", "dateValue": "2020-05-05"}], "displaytype": "preview", "download_preview_message": "", "file_order": 0, "filename": "Estimation of uncertainty in measurement of AC power.pdf", "filesize": [{"value": "2873 Kb"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2873000.0, "url": {"url": "https://meral.edu.mm/record/1792/files/Estimation of uncertainty in measurement of AC power.pdf"}, "version_id": "de57b172-5dbf-462b-bd30-c8fba89bb642"}]}, "item_1583103131163": {"attribute_name": "Journal articles", "attribute_value_mlt": [{"subitem_journal_title": "Proceedings of the First International Conference on Science and Engineering", "subitem_volume": "1"}]}, "item_1583103147082": {"attribute_name": "Conference papaers", "attribute_value_mlt": [{}]}, "item_1583103211336": {"attribute_name": "Books/reports/chapters", "attribute_value_mlt": [{}]}, "item_1583103233624": {"attribute_name": "Thesis/dissertations", "attribute_value_mlt": [{"subitem_supervisor(s)": []}]}, "item_1583105942107": {"attribute_name": "Authors", "attribute_value_mlt": [{"subitem_authors": [{"subitem_authors_fullname": "Thida Swe"}]}]}, "item_1583108359239": {"attribute_name": "Upload type", "attribute_value_mlt": [{"interim": "Other"}]}, "item_1583108428133": {"attribute_name": "Publication type", "attribute_value_mlt": [{"interim": "Other"}]}, "item_1583159729339": {"attribute_name": "Publication date", "attribute_value": "2009"}, "item_1583159847033": {"attribute_name": "Identifier", "attribute_value": "https://uyr.uy.edu.mm/handle/123456789/347"}, "item_title": "Estimation of Uncertainty in Measurement of AC Power", "item_type_id": "21", "owner": "1", "path": ["1582967549708"], "permalink_uri": "http://hdl.handle.net/20.500.12678/0000001792", "pubdate": {"attribute_name": "Deposited date", "attribute_value": "2020-03-05"}, "publish_date": "2020-03-05", "publish_status": "0", "recid": "1792", "relation": {}, "relation_version_is_last": true, "title": ["Estimation of Uncertainty in Measurement of AC Power"], "weko_shared_id": -1}
Estimation of Uncertainty in Measurement of AC Power
http://hdl.handle.net/20.500.12678/0000001792
http://hdl.handle.net/20.500.12678/0000001792353aca68-1642-4f68-9de4-2e65821b2d48
e9b4912a-afeb-4bfd-996c-e1365aba45a0
Name / File | License | Actions |
---|---|---|
Estimation of uncertainty in measurement of AC power.pdf (2873 Kb)
|
|
Publication type | ||||||
---|---|---|---|---|---|---|
Other | ||||||
Upload type | ||||||
Other | ||||||
Title | ||||||
Title | Estimation of Uncertainty in Measurement of AC Power | |||||
Language | en | |||||
Publication date | 2009 | |||||
Authors | ||||||
Thida Swe | ||||||
Description | ||||||
The problem on measurement of AC power in single phase or three-phase networks is always very important. In this paper Test Method is to be applied to Unit Under Test (UUT) Meter which is compared by the known error of Standard Power Meter as reference. This method used to measure the error ofUUT Meter. When estimating the uncertainty of measurement, all components which are of importance in the given situation shall be taken into account using appropriate methods of analysis. In this paper calibration procedure is provided for calibration process of single phase AC power meter using comparison method with its capability as declared. A method for calibration of AC power meter, measurement instruments used in the procedure, processing and presentation of the final results are presented as well. | ||||||
Keywords | ||||||
measurement | ||||||
Identifier | https://uyr.uy.edu.mm/handle/123456789/347 | |||||