Analysis on spatial distribution of fire stations in Chanayethazan Township
San San Nwe
Yi Yi Tint
Khin Thaw Tar
Hla Myint
This research attempts to analyze the spatial distribution of fire stations in Chanayethazan
Township. The main aim of this research is to evaluate whether the number of fire stations are
sufficient for the protection of the outbreaks of the fire or not in the wards of the
Chanayethazan Township. The spatial distribution of fire stations are analyzed by using Hot
Spot Analysis adopted by Getis-Ord Getis and Multi Ring Buffer with the aid of Geographic
Information System (GIS). It is found that the housing types and inadequate water are
important for fire prevention in the township. Seittaramahi, Thirihaymar (West),
Pyigyipyawpwe (West), Dewun (West) are danger zones with fire precaution because of the
largest number of houses, unsystematic road system and inflammable materials. To avoid the
fire outbreaks, systematic utilization of land is essential in Chanayethazan Township.