<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-04-14T21:08:35Z</responseDate>
  <request metadataPrefix="oai_dc" identifier="oai:meral.edu.mm:recid/899" verb="GetRecord">https://meral.edu.mm/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:meral.edu.mm:recid/899</identifier>
        <datestamp>2021-12-13T00:41:58Z</datestamp>
        <setSpec>1582963739756:1582967025340</setSpec>
        <setSpec>user-um</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns="http://www.w3.org/2001/XMLSchema" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>A new scanning system for alpha decay events as calibration sources for range-energy relation in nuclear emulsion</dc:title>
          <dc:creator>Yoshida, J.</dc:creator>
          <dc:creator>Kinbara, S.</dc:creator>
          <dc:creator>Mishina, A.</dc:creator>
          <dc:creator>Nakazawa, K.</dc:creator>
          <dc:creator>Myint Kyaw Soe</dc:creator>
          <dc:creator>Aye Moh Moh Theint</dc:creator>
          <dc:creator>Khin Than Tint</dc:creator>
          <dc:description>A new scanning system named “Vertex picker” has been developed to rapid collect alpha decay events, which are calibration sources for the range-energy relation in nuclear emulsion. A computer-controlled optical microscope scans emulsion layers exhaustively, and a high-speed and high-resolution camera takes their micrographs. A dedicated image processing picks out vertex-like shapes. Practical operations of alpha decay search were demonstrated by emulsion sheets of the KEK-PS E373 experiment. Alpha decays of nearly 28 events were detected in eye-check work on a PC monitor per hour. This yield is nearly 20 times more effective than that by the conventional eye-scan method. The speed and quality is acceptable for the coming new experiment, J-PARC E07.</dc:description>
          <dc:date>2017</dc:date>
          <dc:identifier>http://hdl.handle.net/20.500.12678/0000000899</dc:identifier>
          <dc:identifier>https://meral.edu.mm/records/899</dc:identifier>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
