<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-06-24T06:01:46Z</responseDate>
  <request verb="GetRecord" identifier="oai:meral.edu.mm:recid/618" metadataPrefix="oai_dc">https://meral.edu.mm/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:meral.edu.mm:recid/618</identifier>
        <datestamp>2021-12-13T01:50:14Z</datestamp>
        <setSpec>1582963739756:1582967007954</setSpec>
        <setSpec>user-um</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns="http://www.w3.org/2001/XMLSchema" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Impact of rapid Industrialization of Mandalay on Dokhtawady River</dc:title>
          <dc:creator>Toe Toe Khaing</dc:creator>
          <dc:creator>Myat Lay Nwe</dc:creator>
          <dc:creator>Aye Aye Khaing</dc:creator>
          <dc:creator>Tin Kyaw Oo</dc:creator>
          <dc:creator>Thida Tin</dc:creator>
          <dc:description>Analysis of water quality is required for pollution control, the assessment of&#13; environmental impacts for human beings. In this paper, it is pointed out that how the&#13; effect of industrialization of Mandalay Industrial Zone (II) impacts on Dokhtawady River.&#13; Water quality of three different sites and periods of Dokhtawady River were compared.&#13; These sites are near Shwesaryan Pagoda (Site-I), upper and lower places of Dokhtawady&#13; river that flowed Mandalay industrial sewage Ditch (Site-II and Site-III). The&#13; characteristic properties of water samples were studied by various analytical methods&#13; applying sophisticated instruments such as pH meter, spectrophotometer and conductivity&#13; meter. The physical and chemical parameters were determined such as colour, turbidity,&#13; pH, conductivity, total hardness, total alkalinity, total iron, manganese, chloride, and&#13; sulphate. Heavy metal contamination in water samples were detected by using Atomic&#13; Absorption Spectroscopic method. In addition, the biological examination of water&#13; samples was estimated. The results showed that the water samples were contaminated&#13; with some heavy metals.</dc:description>
          <dc:date>2015</dc:date>
          <dc:identifier>http://hdl.handle.net/20.500.12678/0000000618</dc:identifier>
          <dc:identifier>https://meral.edu.mm/records/618</dc:identifier>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
