<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-10-25T22:07:34Z</responseDate>
  <request verb="GetRecord" identifier="oai:meral.edu.mm:recid/00007058" metadataPrefix="oai_dc">https://meral.edu.mm/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:meral.edu.mm:recid/00007058</identifier>
        <datestamp>2021-12-13T01:57:02Z</datestamp>
        <setSpec>1607925118212</setSpec>
        <setSpec>1607925118212:1608025636517</setSpec>
        <setSpec>user-mub</setSpec>
      </header>
      <metadata>
        <oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns="http://www.w3.org/2001/XMLSchema" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
          <dc:title>Investigation of Leaf Water Content Using Transmission Method</dc:title>
          <dc:creator>Khin Thitsar Shin</dc:creator>
          <dc:creator>Oak Kar Shin</dc:creator>
          <dc:description>This investigation is the water content of betel (Piper Betel Linn) leaves have been
determined based on their mass attenuation characteristics to beta particles. The
transmitted intensities and mass attenuation coefficient for particles of 90Sr
radioactive source with end point energy 0.546MeV is used as beta emitters. The
Geiger Muller Counter is used as detector through the fresh and dry leaves of the
different thickness are measured of beta attenuation for betel leaf sample. These
parameters vary as the amount of water content in selected leaves gets changed. The
mass attenuation coefficient is obtained as the slope of leaf thickness versus
logarithm of relative transmission intensity. The transmission intensity decreases
with increase of water amount in plant leaves. For leaf thickness versus logarithm of
relative transmission intensity provides the attenuation coefficient. The measured
value of mass attenuation coefficient agrees well with that calculated from statistical
regression method. Also, the percentage water content values are determined using
beta attenuation and found to be in close agreement with direct weighing.</dc:description>
          <dc:date>2020-12-01</dc:date>
          <dc:identifier>http://hdl.handle.net/20.500.12678/0000007058</dc:identifier>
          <dc:identifier>https://meral.edu.mm/records/7058</dc:identifier>
        </oai_dc:dc>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
